Chosen Solution

Hello Guys, Hope all are doing well! I was wondering if anyone could help with locating the 6amp fuse on the 820-2330 logic board. Late 2008. The power in ac fuse! MB470. 1286A The board with the angled LVDS connector. Thanks! Roger

Roger, that fuse is reference designator F6905 and it is a 6amp 24V in a 1206 package. Always remember that there is a reason why the fuse may have failed. A simple replacement may not fix your issues.

update

That didn’t blow, what is the board doing so we can figure out the real problem with it? I see boards with lightning damage and even then, that fuse does not blow. If you did manage to do something bad enough to blow that fuse, the board is toast, junk, and goes in the trash. But I’m 99% certain that fuse is fine.